Meclean High-Pressure Trailers, Trailerjets and Trailerpacks with SteamPLUS® steam high-pressure technology:

No mandatory PED inspections and no mandatory periodic re-inspections thanks to patented technology

The '2-Litre Limit' in the European Pressure Equipment Directive (EU PED)

According to EU Directive 2014/68/EU (Annex II, Table 5), equipment for steam or superheated water (above 110 °C) is generally classified as PED Category IV (highest risk category) when three conditions are met simultaneously: a temperature above 110 °C, a pressure above 32 bar, and an internal water volume of the burner/heat exchanger of more than 2 litres. In that case, a pre-commissioning inspection (KvI) and periodic re-inspections are mandatory. For a water volume of 2 litres or less, the installation, even at an operating pressure of up to 500 bar, falls under Article 4(3) (Sound Engineering Practice, SEP) and is not subject to mandatory PED inspection. Thanks to the patented SteamPLUS® technology, with a burner/heat exchanger of up to 2 litres, all Meclean® high-pressure trailers, Trailerjets and Trailerpacks fall outside the mandatory PED Category IV inspections.

PED inspection obligation on high-pressure trailers

meclean® SteamPLUS®

Burner/heat exchanger up to 2 litres


Meclean® uses a patented method to heat the water in small quantities at a time. By deliberately keeping the internal volume below 2 litres, the equipment falls under EU PED "Sound Engineering Practice". As a result, it is legally excluded from the conformity assessment requirements of PED Categories I to IV and from periodic category-based inspections.

PED inspection obligation on high-pressure trailers blast hazard

traditional high-pressure trailers with steam function

Burner/heat exchanger of more than 2 litres


BContains a large energetic risk mass of superheated water under pressure. Under Directive 2014/68/EU, the machine legally falls into PED Category IV (the highest risk class). This requires a comprehensive assessment by a Notified Body, mandatory certification of the complete assembly, periodic re-inspections, and a mandatory re-inspection after repairs.

With a Category IV high-pressure trailer, you are bound to legally required periodic re-inspections and the associated administrative burden.

With meclean®, this inspection obligation does not arise, thanks to the smart, patented design. The result?
No mandatory PED re-inspections, freedom in the choice of parts, and a lower total cost of ownership (TCO) over the service life of your machine.

COMPARISON TABLE

(Tip: swipe right within the table)

High-pressure trailers with steam function and a burner/heat exchanger of more than 2 litres meclean® SteamPLUS®
Burner/heat exchanger capacity More than 2 litres Up to 2 litres
PED classification PED Category IV (the highest risk class—“Very high risk”) Article 4, paragraph 3 (Sound Engineering Practice)
Mandatory PED inspection Yes, legally required (via a Notified Body) No
Mandatory periodic re-inspections Yes, periodically required, with associated inspection costs and downtime No, so no recurring PED inspection costs
After repairs A mandatory inspection or re-inspection by an inspection authority is required following repairs or major modifications to the pressure-retaining part No mandatory PED re-inspection
Parts Components are tied to the certification of the assembly, so there is no freedom to choose components - instead, there is “vendor lock-in.” Freedom in Choosing Parts
Patented SteamPLUS® technology Not applicable Yes
  • Why doesn’t a meclean® high-pressure trailer need a mandatory inspection?

    High-pressure trailers with a water volume of more than 2 liters fall under PED Category IV and are therefore subject to mandatory inspections. Thanks to the patented SteamPLUS® technology, the water volume in meclean® trailers remains under 2 liters. As a result, no mandatory PED inspection applies. A well-thought-out design that limits the risk right at the source - while maintaining maximum cleaning power.

  • Who is responsible for PED inspections?

    The manufacturer is responsible for the conformity and marking of the machine before it is placed on the market. The owner or employer is responsible for complying with inspection requirements during use at the workplace. For high-pressure trailers that fall under PED Category IV, this means mandatory inspections and re-inspections. With meclean® high-pressure trailers, the burner/heat exchanger of up to 2 litres means no mandatory PED inspection applies.

  • How can I check which PED category my current high-pressure trailer falls under?

    You can easily determine the PED classification of your steam or high-pressure trailer via the official nameplate on the machine or in the accompanying CE technical file (the EU Declaration of Conformity). When checking the nameplate, pay attention to the following characteristics:


    🔴 PED Category IV (Mandatory inspection required):


    Is the working temperature above 110 °C and the pressure above 32 bar? Then check the fluid volume (V) of the burner/heat exchanger:


    - is a capacity of more than 2 liters stated here (for example 3.5 L or 5.0 L)? Then the machine falls into the highest risk category (PED Category IV).


    - Nameplate characteristic: for Category IV, the CE marking must be followed by a 4-digit identification number of the Notified Body (NoBo, such as CE 0036, CE 0620, or the NoBo number of SGS, Kiwa, TÜV, or Dekra).


    🟢 Article 4, Paragraph 3 SEP (100% Inspection-exempt - meclean®):


    Does the nameplate or technical file state V ≤ 2 L or Article 4, Paragraph 3 SEP (Sound Engineering Practice)? Then the machine falls under the statutory inspection exemption of Article 4, Paragraph 3.


    - Nameplate characteristic: there is no 4-digit NoBo number behind the CE mark. The PED Directive explicitly prohibits applying a NoBo number to SEP equipment (the CE marking on the trailer itself is naturally present based on the European Machinery Directive 2006/42/EC).


    ⚠️ Do the temperature (≤ 110 °C) or pressure (≤ 32 bar) remain below the threshold values?


    Then the precise classification depends on the other specific machine parameters. In that case, consult the CE technical file or the manufacturer.


    In summary:

    Does your current high-pressure trailer have a burner capacity of more than 2 liters with a 4-digit NoBo number behind the CE mark? Then you are legally subject to an Initial Inspection before Use and recurring re-inspections. 


    With meclean® High-Pressure Trailers, the water capacity remains under 2 liters thanks to patented SteamPLUS® technology, exempting you from inspections and eliminating the need to manage a PED inspection schedule.

  • What are the risks if an inspection-liable high-pressure trailer is not re-inspected on time?

    Organising mandatory inspections generally falls under the statutory duty of care of the employer or owner. If a PED Category IV high-pressure trailer is put into service without a valid pre-commissioning inspection (KvI) or re-inspection report, you may face the following risks:


    Supervision and enforcement: during an inspection, the supervisory authority (in the Netherlands, the Dutch Labour Inspectorate) may shut down the machine and impose an administrative fine.


    Liability and insurance: if an incident or damage occurs involving a burner/heat exchanger that has not been inspected in accordance with legal requirements, the insurer may, depending on the policy terms, refuse coverage.


    Costs after an expired inspection: if the inspection period has expired, a new inspection may be required. This can mean additional costs and downtime.


    For meclean® high-pressure trailers with a burner/heat exchanger of up to 2 litres, no mandatory PED inspection applies, so there is also no PED re-inspection deadline that can expire.

  • Does a compact burner/heat exchanger (< 2 L) mean lower steam output or temperature?

    Absolutely not. The difference lies not in the temperature or steam output, but in the way the water is heated. Traditional systems keep a large reservoir of more than 2 litres of superheated water under continuous pressure to produce steam. The patented Meclean® SteamPLUS® technology works as follows: the water is heated in small, continuous quantities. As a result, the machine delivers an extremely high steam capacity (up to 150 °C) and up to 250 bar of regular working pressure in SteamPLUS® mode, without a dangerous large mass of superheated water under pressure being present.

  • Is a machine without a mandatory PED inspection also safe to use?

    No mandatory PED inspection does not mean that no requirements apply. A meclean® high-pressure trailer is also supplied with CE marking, an EU declaration of conformity and a comprehensive manual, and the general legal requirements for safe use and maintenance continue to apply. The difference lies in the design: thanks to SteamPLUS® technology, the burner/heat exchanger stays within 2 litres, so the machine falls under Article 4(3) of Directive 2014/68/EU (Sound Engineering Practice) and no mandatory PED inspection applies.

  • What costs can mandatory inspections entail over the service life of a high-pressure trailer?

    For a PED Category IV high-pressure trailer, the costs go beyond the inspection fee alone. Consider the pre-commissioning inspection (KvI), periodic re-inspections, downtime during the inspection, and the administration around inspection reports and deadlines. For meclean® high-pressure trailers with a burner/heat exchanger of up to 2 litres, no mandatory PED inspection applies, so these PED inspection costs do not arise.

  • What happens when a repair is carried out on a meclean® burner or heat exchanger?

    With meclean®, no mandatory re-inspection by an external inspection body is required after a repair. Regular qualified maintenance is sufficient. For PED Category IV steam equipment, regulations mandate that physical repairs to pressure-retaining components must first be reported to and re-examined by an accredited inspection body, leading to operational downtime and additional inspection fees.

  • Can I use universal parts and hoses on a meclean® High-Pressure Trailer?

    Yes. Because a meclean® high-pressure trailer falls under **Article 4, Paragraph 3 SEP (Sound Engineering Practice)**, you are not bound to a rigid, certified 'PED Category IV assembly'. You retain full freedom to use high-quality universal hoses, spray guns, and lances. On Category IV trailers, using non-OEM replacement parts can invalidate the overall assembly certification, resulting in strict manufacturer vendor lock-in.

  • What does a high-pressure trailer without a mandatory PED inspection mean for my fleet and planning?

    If you operate several high-pressure trailers, for example as a cleaning company or a municipality, each machine subject to inspection has its own inspection schedule, with deadlines that must be monitored and periods when the machine cannot be used. With meclean® high-pressure trailers with a burner/heat exchanger of up to 2 litres, no mandatory PED inspection applies, so there is no PED inspection schedule to manage. This keeps your machines more available and your planning clearer.

Safety by design. No inspections required during use.

Cleaning professionals and public-sector organisations benefit from the patented meclean® SteamPLUS® technology. Not only through its impressive performance, but also through its unique advantage: a burner/heat exchanger with a capacity of up to 2 litres means no mandatory PED inspections. Save significantly on inspection and downtime costs over the machine’s service life and retain your operational freedom.


Curious about the unique cleaning performance of a meclean® high-pressure trailer, Trailerjet or Trailerpack? Schedule a no-obligation on-site demonstration or request a competitive quote right away.

We will only contact you in connection with this completed form. Your data will not be used for marketing purposes.

Demo-aanvraag via PED-Keuringsplicht landingpage